Discharge through an air gap located in the same room as the water heater.
Hot water heater pressure relief valve discharge pipe installation.
Temperature and pressure relief valves shall be installed so that the sensing element of the valve extends into the heater tank and monitors the temperature in the top 6 inches of the heater or tank.
A trapped tpr dischage pipe is a common defect when a replacement water heater s tpr valve is lower than the original one and the installer connects to the exisitng discharge piping at the wall.
Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap.
So this release of its pressure causes your hot water tank overflow pipe dripping towards the floor where the hot water heater is placed.
Yes part of the video i have the camera between my teeth lol you ca.
Pressure relief valve installation mounting.
Step 2 hold the tpr valve with the slip joint pliers.
Mount prvs in a vertical position which means upright and with the spindle vertical.
8 termination of the tpr drain pipe cannot be more than 6 inches or less than two pipe diameters above the floor ground or waster receptor flood rim level.
For flanged valves be sure to draw the bolts down evenly.
This temperature pressure relief valve is attached to the discharge pipe.
A valve installed in any position other than vertical might not perform correctly.
The discharge piping serving a pressure relief valve temperature relief valve or combination valve shall.
Whether you re installing a new indoor or outdoor tankless water heater or replacing a pressure release valve include a length of pvc pipe as a discharge line.
Every relief valve which is designed to discharge water or steam shall be connected to a discharge pipe.
These numbers will be printed right on the valve or on a tag attached to the.
Not be directly connected to the drainage system.
This is a very simple video on how to replace add a discharge pipe on a water heater.
Thread the tpr valve clockwise into the pressure relief fitting on the water heater and tighten it by hand until it is tight.
It s designed to release the pressure when there is too much of a load built up inside the water heater.
This is especially crucial for cast iron valves.
The tpr valve will activate if either water temperature measured in degrees fahrenheit or pressure measured in pounds per square inch psi exceed safe levels.