The wt8840 water heater control is designed for use 0 5 psi 14 0 in.
Honeywell water heater gas control valve manual.
Check the full rate manifold pressure listed on the warning appliance nameplate.
The honeywell valve uses a thermopile instead of a thermocouple as did previous designs.
The wv4460e provides these features.
Gas regulation and manual valve features intermittent spark to pilot ignition flame supervision using flame rectification sensing through the spark rod.
Retain your original receipt as proof of purchase.
The wv4460e water heater control system is designed for power vent water heater applications.
Use a wrench on the square end of the water heater control.
Page 7 wv4460e power vent water heater controls perform gas leak test gas input and burner ignition check and adjustment 1.
Sequence of operations wv4460e.
Connect the pipe to the water heater control inlet and outlet.
Water heaters covered by this handbook are equipped with honeywell gas control valve thermostats.
Page 2 high humidity or dripping water m36122 dripping water can cause the control to fail.
Maximum torque on the inlet is 40 ft lbs.
Maximum torque on the outlet is 30 ft lbs.
Water heater control full rate fire or explosion hazard outlet pressure should match this rating.
When referring to your water heater always have the information listed on the data plate readily available.
A data plate identifying your water heater can be found next to the gas control valve thermostat.
W c maximum inlet pressure in standing pilot applications using an immersion allowed for proper operation.